Quality
A process you can audit beats a sentence about reliability.
The real risk in an overseas purchase is not a modest specification — it is batch-to-batch drift. This page states what we measure, what we judge against, how long we keep it, and what you can check at destination.
Six gates a batch passes
From raw material to retained sample
Raw material intake
Macromonomer sampled per lot for hydroxyl value, water and unsaturation; acrylic acid for purity and inhibitor content. A failing lot goes back — it does not enter the tank farm.
In-process control
Feed rate, reaction temperature and hold time logged per batch; conversion and viscosity checked mid-run. An out-of-band reading stops the line rather than travelling downstream.
Batch testing
Solids, pH, density, chloride and total alkali on every batch; viscosity and appearance as supporting criteria.
Application check
Paste flow and mortar water reduction are the release gates on performance; new formulations or changed raw materials trigger a concrete-level check as well.
Retained sample
At least 12 months of retained sample per batch, archived with the COA. If a question comes back from destination, this is the bottle that gets re-tested.
Traceability
A batch number traces back to the raw-material lot, the reactor, the shift and the inspection record. A complaint lands on one batch, not on "production around that time".
Standards we work to
| Standard | Scope |
|---|---|
GB 8076-2008 | Concrete admixtures |
JG/T 223-2017 | Polycarboxylate high-performance water reducers |
ASTM C494/C494M | Type F and Type G chemical admixtures |
EN 934-2 | Admixtures for concrete, mortar and grout |
The standard numbers describe the test methods and the basis for judgement. Product is supplied to the contractual TDS, tested by the methods in those standards; where third-party reports are needed, testing goes to a laboratory recognised in the destination country.
The data you receive
Every COA carries measured values rather than a pass stamp. These five are always reported:
| Solid content | 50 ± 1 % |
|---|---|
| pH at 25 °C | 6.0–8.0 |
| Density at 25 °C | 1.07–1.11 g/cm³ |
| Chloride | ≤ 0.05 % |
| Total alkali | ≤ 2.0 % |
The ranges above are common to the standard grades; the grade TDS and the batch COA govern in each case.
Documents
Download or request, no account
TDS
A data sheet per grade: recommended dosage, typical values, scope and storage. Downloadable from the list below, or by email where not yet listed.
SDS
16-section GHS format, English in stock; other languages on request, stating destination and use.
COA
Supplied with the goods, or sent for approval before the container is loaded.
TDS by grade
PDF · six grades- CU-100Water-reducingon request →
- CU-200Retainon request →
- CU-300Earlyon request →
- CU-400Clay-toleranton request →
- CU-500Viscosity-reducingon request →
- CU-600Shrinkage-reducingon request →
Ask for a real COA
Name a grade and you get the last three batches. Batch-to-batch variation is easier to read in numbers than in adjectives.